Specifications of C8051F902-GM

Program Memory Type
FLASH
Program Memory Size
8KB (8K x 8)
Package / Case
24-QFN
Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
16
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
0.9 V ~ 3.6 V
Data Converters
A/D 15x10/12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
C8051F9x
Core
8051
Data Ram Size
768 B
Interface Type
UART
Maximum Clock Frequency
25 MHz
Number Of Timers
4
Operating Supply Voltage
0.9 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F912DK
Minimum Operating Temperature
- 40 C
On-chip Adc
12 bit
Package
24QFN EP
Device Core
8051
Family Name
C8051F90x
Maximum Speed
25 MHz
Data Bus Width
8 Bit
Number Of Programmable I/os
16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1848-5
C8051F91x-C8051F90x
15.2. Preparing for a CRC Calculation
To prepare CRC0 for a CRC calculation, software should select the desired polynomial and set the initial
value of the result. Two polynomials are available: 0x1021 (16-bit) and 0x04C11DB7 (32-bit). The CRC0
result may be initialized to one of two values: 0x00000000 or 0xFFFFFFFF. The following steps can be
used to initialize CRC0.
15.3. Performing a CRC Calculation
Once CRC0 is initialized, the input data stream is sequentially written to CRC0IN, one byte at a time. The
CRC0 result is automatically updated after each byte is written. The CRC engine may also be configured to
automatically perform a CRC on one or more Flash sectors. The following steps can be used to
automatically perform a CRC on Flash memory.
15.4. Accessing the CRC0 Result
The internal CRC0 result is 32-bits (CRC0SEL = 0b) or 16-bits (CRC0SEL = 1b). The CRC0PNT bits
select the byte that is targeted by read and write operations on CRC0DAT and increment after each read or
write. The calculation result will remain in the internal CR0 result register until it is set, overwritten, or
additional data is written to CRC0IN.
154
1. Select a polynomial (Set CRC0SEL to 0 for 32-bit or 1 for 16-bit).
2. Select the initial result value (Set CRC0VAL to 0 for 0x00000000 or 1 for 0xFFFFFFFF).
3. Set the result to its initial value (Write 1 to CRC0INIT).
1. Prepare CRC0 for a CRC calculation as shown above.
2. Write the index of the starting page to CRC0AUTO.
3. Set the AUTOEN bit in CRC0AUTO.
4. Write the number of Flash sectors to perform in the CRC calculation to CRC0CNT. 
5. Write any value to CRC0CN (or OR its contents with 0x00) to initiate the CRC calculation. The
6. Clear the AUTOEN bit in CRC0AUTO.
7. Read the CRC result using the procedure below.
Note: Each Flash sector is 512 bytes on ‘F91x and ‘F90x devices.
CPU will not execute code any additional code until the CRC operation completes. See the
note in SFR Definition 15.1. CRC0CN: CRC0 Control for more information on how to
properly initiate a CRC calculation.