AT91SAM7L64-AU Atmel, AT91SAM7L64-AU Datasheet - Page 175

MCU ARM7 64K HS FLASH 128-LQFP

AT91SAM7L64-AU

Manufacturer Part Number
AT91SAM7L64-AU
Description
MCU ARM7 64K HS FLASH 128-LQFP
Manufacturer
Atmel
Series
AT91SAMr
Datasheets

Specifications of AT91SAM7L64-AU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
36MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LCD, POR, PWM, WDT
Number Of I /o
80
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
6K x 8
Voltage - Supply (vcc/vdd)
1.55 V ~ 1.8 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
128-LQFP
Controller Family/series
AT91SAM7xxx
No. Of I/o's
80
Ram Memory Size
6KB
Cpu Speed
36MHz
No. Of Timers
1
Rohs Compliant
Yes
Processor Series
AT91SAMx
Core
ARM7TDMI
Data Bus Width
32 bit
Data Ram Size
6 KB
Interface Type
2-Wire, SPI, USART
Maximum Clock Frequency
36 MHz
Number Of Programmable I/os
80
Number Of Timers
3
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
JTRACE-ARM-2M, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
AT91SAM-ICE, AT91-ISP, AT91SAM7L-EK
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 4 Channel
For Use With
AT91SAM7L-STK - KIT EVAL FOR AT91SAM7LAT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7L64-AU
Manufacturer:
Atmel
Quantity:
10 000
21.4.1
6257A–ATARM–20-Feb-08
DBGU Serial Port
Table 21-1.
Note:
Communication is performed through the DBGU serial port initialized to 115200 Baud, 8, n, 1.
The Send and Receive File commands use the Xmodem protocol to communicate. Any terminal
performing this protocol can be used to send the application file to the target. The size of the
Command
O
o
H
h
W
w
S
R
G
V
• Write commands: Write a byte (O), a halfword (H) or a word (W) to the target.
• Read commands: Read a byte (o), a halfword (h) or a word (w) from the target.
• Send a file (S): Send a file to a specified address
• Receive a file (R): Receive data into a file from a specified address
• Go (G): Jump to a specified address and execute the code
• Get Version (V): Return the SAM-BA boot version
– Once the communication interface is identified, the application runs in an infinite
– Address: Address in hexadecimal.
– Value: Byte, halfword or word to write in hexadecimal.
– Output: ‘>’.
– Address: Address in hexadecimal
– Output: The byte, halfword or word read in hexadecimal following by ‘>’
– Address: Address in hexadecimal
– Output: ‘>’.
– Address: Address in hexadecimal
– Output: ‘>’
– Address: Address to jump in hexadecimal
– Output: ‘>’
– Output: ‘>’
loop waiting for different commands as given in
NbOfBytes
There is a time-out on this command which is reached when the prompt ‘>’ appears before the
end of the command execution.
Commands Available through the SAM-BA Boot
Action
write a byte
read a byte
write a half word
read a half word
write a word
read a word
send a file
receive a file
go
display version
: Number of bytes in hexadecimal to receive
AT91SAM7L128/64 Preliminary
Argument(s)
Address, Value#
Address,#
Address, Value#
Address,#
Address, Value#
Address,#
Address,#
Address, NbOfBytes#
Address#
No argument
Table
21-1.
Example
O200001,CA#
o200001,#
H200002,CAFE#
h200002,#
W200000,CAFEDECA#
w200000,#
S200000,#
R200000,1234#
G200200#
V#
175