UPD78F0890GK(A)-GAJ-AX NEC, UPD78F0890GK(A)-GAJ-AX Datasheet - Page 369

8BIT MCU, 128K FLASH, 7K RAM, LQFP

UPD78F0890GK(A)-GAJ-AX

Manufacturer Part Number
UPD78F0890GK(A)-GAJ-AX
Description
8BIT MCU, 128K FLASH, 7K RAM, LQFP
Manufacturer
NEC
Datasheet

Specifications of UPD78F0890GK(A)-GAJ-AX

Controller Family/series
UPD78F
No. Of I/o's
55
Ram Memory Size
7KB
Cpu Speed
20MHz
No. Of Timers
10
No. Of Pwm
RoHS Compliant
Core Size
8bit
Program Memory Size
128KB
Oscillator Type
External, Internal
(2) Communication operation
In the 3-wire serial I/O mode, data is transmitted or received in 8-bit units. Each bit of the data is transmitted or
received in synchronization with the serial clock.
Data can be transmitted or received if bit 6 (TRMD1n) of serial operation mode register 1n (CSIM1n) is 1.
Transmission/reception is started when a value is written to transmit buffer register 1n (SOTB1n). In addition,
data can be received when bit 6 (TRMD1n) of serial operation mode register 1n (CSIM1n) is 0.
Reception is started when data is read from serial I/O shift register 1n (SIO1n).
However, communication is performed as follows if bit 5 (SSE11) of CSIM11 is 1 when serial interface CSI11 is in
the slave mode.
<1> Low level input to the SSI11 pin
<2> High level input to the SSI11 pin
<3> Data is written to SOTB11 or data is read from SIO11 while a high level is input to the SSI11 pin, then a low
<4> A high level is input to the SSI11 pin during transmission/reception or reception
After communication has been started, bit 0 (CSOT1n) of CSIM1n is set to 1. When communication of 8-bit data
has been completed, a communication completion interrupt request flag (CSIIF1n) is set, and CSOT1n is cleared
to 0. Then the next communication is enabled.
Cautions 1. Do not access the control register and data register when CSOT1n = 1 (during serial
Remark n = 0, 1
→ Transmission/reception is started when SOTB11 is written, or reception is started when SIO11 is read.
→ Transmission/reception or reception is held, therefore, even if SOTB11 is written or SIO11 is read,
level is input to the SSI11 pin
→ Transmission/reception or reception is started.
→ Transmission/reception or reception is suspended.
transmission/reception or reception will not be started.
2. When using serial interface CSI11, wait for the duration of at least one clock before the
communication).
clock operation is started to change the level of the SSI11 pin in the slave mode;
otherwise, malfunctioning may occur.
CHAPTER 15 SERIAL INTERFACES CSI10 AND CSI11
User’s Manual U17554EJ4V0UD
369