S912XEQ384J3MALR Freescale Semiconductor, S912XEQ384J3MALR Datasheet - Page 237

no-image

S912XEQ384J3MALR

Manufacturer Part Number
S912XEQ384J3MALR
Description
S912XEQ Series 16 Bit 50 Mhz 384 KB Flash 24 KB Ram Microcontroller - LQFP-112
Manufacturer
Freescale Semiconductor
Datasheet
4.4
The MPU module provides memory protection for accesses coming from multiple masters in the system.
This is done by monitoring bus traffic of each master and compare this with the configuration information
from a set of eight programmable descriptors located in the MPU module. If the MPU module detects an
access violation caused by the S12X CPU, it will assert the CPU access violation interrupt signal. If the
MPU module detects an access violation caused by a bus master other than the S12X CPU, it raises an
access error signal. Please refer to the documentation chapter of the individual master modules (i.e.
XGATE, etc.) for more information about the access error condition.
Violating accesses are not executed. The return value of a violating read access is undefined for both 8 bit
and 16 bit accesses.
4.4.1
Each of the eight protection descriptors can be used to restrict the allowed types of memory accesses for
a given memory range. Each of these memory ranges can cover up the entire 23 bits global memory range
(8 MBytes).
The descriptors are banked in the MPU module register map.
Each descriptor can be selected for modifying using the SEL bits in the MPU Descriptor Select (MPUSEL)
register.
Table 4-14
descriptors.
The granularity of each descriptor is 8 bytes. This means the protection comparators in the MPU module
cover only address bits [22:3] of each access. The lower address bits [2:0] are ignored.
Freescale Semiconductor
Functional Description
gives an overview of the types of accesses that can be configured using the protection
Protection Descriptors
Accesses from BDM are not restricted. BDM hardware accesses always
bypass the MPU module. During execution of BDM firmware code S12X
CPU accesses are masked from the MPU module as well.
A mis-aligned word access to the upper boundary address of a descriptor is
always flagged as an access violation.
MC9S12XE-Family Reference Manual Rev. 1.24
WP
0
0
1
1
Table 4-14. Access Types
NEX
0
1
0
1
NOTE
NOTE
read, write and execute
read and execute
read, write
read only
Meaning
Chapter 4 Memory Protection Unit (S12XMPUV1)
237