Z8018010PSG Zilog, Z8018010PSG Datasheet - Page 30

IC 10MHZ Z180 CMOS ENH MPU 64DIP

Z8018010PSG

Manufacturer Part Number
Z8018010PSG
Description
IC 10MHZ Z180 CMOS ENH MPU 64DIP
Manufacturer
Zilog
Datasheets

Specifications of Z8018010PSG

Processor Type
Z180
Features
8-Bit, Enhanced Z80 Megacell
Speed
10MHz
Voltage
5V
Mounting Type
Through Hole
Package / Case
64-DIP (0.750", 19.05mm)
Processor Series
Z8018xx
Core
Z80
Data Bus Width
8 bit
Maximum Clock Frequency
10 MHz
Number Of Timers
2
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 70 C
Mounting Style
Through Hole
Minimum Operating Temperature
0 C
Core Size
8bit
Cpu Speed
10MHz
Digital Ic Case Style
DIP
No. Of Pins
64
Supply Voltage Range
4.5V To 5.5V
Operating Temperature Range
0°C To +70°C
Svhc
No SVHC (18-Jun-2010)
Base Number
8018010
Rohs Compliant
Yes
Clock Frequency
10MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-3889
Z8018010PSG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8018010PSG
Manufacturer:
Zilog
Quantity:
40
OPERATION MODES
Operation Mode Control Register
Bit
Bit/Field
R/W
Reset
Note: R = Read W = Write X = Indeterminate? = Not Applicable
M1E
R/W
7
1
The Z8X180 can be configured to operate like the Hitachi HD64180. This
functionality is accomplished by allowing user control over the M1,
IORQ, WR, and RD signals. The Operation Mode Control Register
(OMCR), illustrated in Figure 5, determines the M1 options, the timing of
the IORQ, RD, and WR signals, and the RETI operation.
Figure 5.
M1E (M1 Enable): This bit controls the M1 output and is set to a
RESET.
When M1E is
cycle, the INT0 acknowledge cycle, and the first machine cycle of the
NMI acknowledge. This action also causes the M1 signal to be Active
during both fetches of the RETI instruction sequence, and may cause
corruption of the external interrupt daisy chain. Therefore, this bit must be
0
asserted Low only during the refetch of the RETI instruction sequence
and the INT0 acknowledge cycle (Figure 6).
for the Z8X180. When M1E is
M1TE
W
6
1
Operation Mode Control Register
1
, the M1 output is asserted Low during the Op Code fetch
R/W
IOC
5
1
4
0
the M1 output is normally inactive and
Family MPU User Manual
Reserved
UM005003-0703
Z8018x
1
during
0
15

Related parts for Z8018010PSG