Installation and Configuration—IXB2850
6.6
6.7
6.8
6.9
6.9.1
Note:
Note:
January 2007
Document Number: 05-2443-006
Software Installation
IXB2850 boards are delivered without any software preinstalled (only firmware is
preinstalled). It is the customer’s responsibility to prepare the Linux kernel, file system
and target application. This document provides information on downloading software to
an IXB2850 board (that is, SSU functionality) and running software from a remote
server. See
Boot Monitor Operation
See
Monitor (RedBoot*).
Power-On Self Test
The Board Management Controller (BMC) and the Network Processor (NP) both perform
Power On Self Test (POST). See
and
Diagnostics
The diagnostics are handled by a separate application (outside of the BootROM). By
default, diagnostics are executed under the control of a diagnostic command line
interface (DIAG> prompt). However, the diagnostics can be executed from the Boot
Monitor. This is done by loading the diagnostics image into SDRAM from flash memory,
TFTP server (Ethernet debug port), or through a serial (UART) port.
Running the Diagnostics
To run the diagnostics for the board, perform the following:
If the “Cannot find valid SSU header in 0x01000000-0x012e0000” message is
displayed, then either the
Verify that the image is valid (has the correct length, etc.), then try again.
The
image for your IXB2850 board may have a different name. Ensure that you use the
exact image name shown in the
2. Open both of the board’s clamps slightly to initiate removal of the board. Do not
3. Once the blue H/S indicator is lit, completely open the board clamps to disconnect
4. Remove the board from the chassis.
1. Enter the following command to ensure that you are using the proper file names for
2. Load the diagnostics image, as it appears in the fis list command output, from
remove the board from the chassis backplane. The green HEALTH indicator goes
out and after a few seconds the blue H/S indicator is lit.
the board from the chassis backplane slot.
the diagnostic image:
flash:
Section 9.4, “Boot Monitor” on page 110
Section 9.4.3, “NPU Power On Self Test” on page 112
diag
RedBoot> fis list
RedBoot> fis load -s diag
diagnostics image name is shown for example purposes only. The diagnostics
Section 11.2, “Safe System Upgrade” on page 131
diag
image does not contain an SSU header or it is invalid.
Section 8.1.2.1, “BMC Power On Self Test” on page 86
fis list
command output (step 1 above).
Intel NetStructure
for a detailed description of the Boot
for more information.
®
IXB2850 Packet Processing Boards
for more information.
TPS