IXB28504XGBEFS Intel, IXB28504XGBEFS Datasheet - Page 249

no-image

IXB28504XGBEFS

Manufacturer Part Number
IXB28504XGBEFS
Description
Manufacturer
Intel
Datasheet

Specifications of IXB28504XGBEFS

Lead Free Status / Rohs Status
Compliant
Diagnostics—IXB2850
January 2007
Document Number: 05-2443-006
ports -- list (demarcated by commas) of ports to be tested
For FIC C48 DB1/1 and DB1/2 should be specified to point the interface when
temporary solution is used (FIC inserted in DB slot - then the DB1 flow is tested)
• SM - media system loopback - NPU generate, receive and check frames, loopback
• SP - PHY system loopback - NPU generate, receive and check frames, loopback on
• R - all MAC and PHY registers test
• RM - all MAC registers test
• RMD - MAC default registers check
• RMU - MAC update registers test
• RP - all PHY registers test
• RPD - MAC default registers test
• RPU - PHY update registers test
• RF - all Fiber MIC registers test
• RFD - default Fiber MIC registers test
• RFU - update Fiber MIC registers test
• RC - all Copper MIC registers test (not applicable to IXB2850)
• RCD - default Copper MIC registers test (not applicable to IXB2850)
• RCU - update Copper MIC registers test (not applicable to IXB2850)
• D - disable test for selected mode
• C - short counter show
• CMF - Full media hardware counter show (also for C48)
• CMT -transmit media hardware counter show (also for C48)
• CMR - receive media hardware counter show (also for C48)
• CMO - other media hardware counter show (also for C48)
• CPF - full PHY hardware counter show (also for C48)
• CPT - transmit PHY hardware counter show (also for C48)
• CPR - receive PHY hardware counter show (also for C48)
• CPO - other PHY hardware counter show (also for C48)
• H - help
• DB1/1 - interface number '1' on daughter card number '1'
• DB1/2 - interface number '2' on daughter card number '1'
• DB1/3 - interface number '3' on daughter card number '1'
• DB1/4 - interface number '4' on daughter card number '1'
• DB1 - all interfaces on daughter card number '1'
• DB2/1 - interface number '1' on daughter card number '2'
• DB2/2 - interface number '2' on daughter card number '2'
• DB2/3 - interface number '3' on daughter card number '2'
• DB2/4 - interface number '4' on daughter card number '2'
• DB2 - all interfaces on daughter card number '2'
on media. In the case of FIC C48 it configures so called shallow loopback.
PHY. In the case of FIC C48 it configures so called deep loopback.
Intel NetStructure
®
IXB2850 Packet Processing Boards
TPS
249