IXB28504XGBEFS Intel, IXB28504XGBEFS Datasheet - Page 147

no-image

IXB28504XGBEFS

Manufacturer Part Number
IXB28504XGBEFS
Description
Manufacturer
Intel
Datasheet

Specifications of IXB28504XGBEFS

Lead Free Status / Rohs Status
Compliant
Maintenance—IXB2850
Note:
11.3.2
January 2007
Document Number: 05-2443-006
All mentioned above devices are programmable by the BMC with the exception of the
BMC CPLD and JTAG router CPLD. These two latter CPLD are vital to the overall board
operation and can be programmed only using the JTAG interface.
When upgrading CPLDs, the following switches must be set as indicated:
The CPLDs may be upgraded using the BMC console.
The procedures for upgrading CPLDs on the Gigabit Ethernet Mezzanine card, MIC and
FIC are similar and therefore not repeated here.
Local Software Upgrade of All Images at One Time
Software upgrade may be performed using the IXP28x0_upgrade.bin appimage that
contains all upgradeable images.
1. Enter the CPLD section:
2. Upload the baseboard CPLD:
3. Upgrade the baseboard CPLD:
4. Upload the NP module CPLD:
5. Upgrade the NP Module CPLD:
• MMC #1 and #2 CPLDs (MMC #1 is not applicable to IXB2850 boards)
• MIC #1 and #2 CPLDs (MIC #1 is not applicable to IXB2850 boards)
• FIC CPLD
• S1 on the baseboard: 1,2,3,4,5,6,7=OFF, S8=ON
• SW1 on the Gigabit Ethernet Mezzanine card:
• SW1 on the FIC: 1=Unchanged, 2,3=ON, 4=OFF
q
y
u
1
l
<upload ixmb2801_4_rohs5.bin by XModem>
u
0
l
<upload ixnpm2800_3A_rohs5.bin by XModem>
— For the Mezzanine Card upgrade: 1=Unchanged, 2,3=ON, 4=OFF
— For the MIC upgrade: 1=Unchanged, 2=OFF, 3,4=ON
Intel NetStructure
®
IXB2850 Packet Processing Boards
TPS