peb2256 Infineon Technologies Corporation, peb2256 Datasheet - Page 90

no-image

peb2256

Manufacturer Part Number
peb2256
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb2256H
Manufacturer:
Infineon
Quantity:
5
Part Number:
peb2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb2256HV1.2
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2256HV1.2
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
peb2256HV1.2
Manufacturer:
XILINX
0
Part Number:
peb2256HV1.4
Manufacturer:
INFINEON
Quantity:
1 831
Part Number:
peb2256R V1.2
Quantity:
5 510
4.3
4.3.1
Alarm Indication Signal: Detection and recovery is flagged by bit FRS0.AIS and
ISR2.AIS. Transmission is enabled by bit FMR1.XAIS.
Loss-Of-Signal: Detection and recovery is flagged by bit FRS0.LOS and ISR2.LOS.
Remote Alarm Indication: Detection and release is flagged by bit FRS0.RRA, RSW.RRA
and ISR2.RA/RAR. Transmission is enabled by bit XSW.XRA.
AIS in time slot 16: Detection and release is flagged by bit FRS1.TS16AIS and
ISR3.AIS16. Transmission is enabled by writing all ones in registers XS(16:1).
LOS in time slot 16: Detection and release is flagged by bit FRS1.TS16LOS.
Transmission is enabled by writing all zeros in registers XS(16:1).
Remote Alarm in time slot 16: Detection and release is flagged by bit FRS1.TS16RA and
ISR3.RA16. Transmission is enabled by bit XS1.2.
Transmit Line Shorted: Detection and release is flagged by bit FRS1.XLS and
ISR1.XLSC.
Transmit Ones-Density: Detection and release is flagged by bit FRS1.XLO and
ISR1.XLSC.
Table 20
Alarm
Loss-Of-Signal
(LOS)
Alarm Indication
Signal (AIS)
Remote Alarm
(RRA)
Data Sheet
Additional Receive Framer Functions (E1)
Error Performance Monitoring and Alarm Handling
Summary of Alarm Detection and Release (E1)
Detection Condition
no transitions (logical
zeros) in a programmable
time interval of 16 to 4096
consecutive pulse periods.
Programmable receive
input signal threshold
FMR0.ALM = 0:
less than 3 zeros in
250 µs and loss of frame
alignment declared
FMR0.ALM = 1:
less than 3 zeros in
each of two consecutive
250-µs periods
bit 3 = 1 in time slot 0 not
containing the FAS word
90
Clear Condition
programmable number of ones (1
to 256) in a programmable time
interval of 16 to 4096 consecutive
pulse periods. A one is a signal
with a level above the
programmed threshold.
FMR0.ALM = 0:
more than 2 zeros in
250 µs
FMR0.ALM = 1:
more than 2 zeros in each of two
500-µs periods
set conditions no longer detected.
Functional Description E1
FALC56 V1.2
PEB 2256
2002-08-27