peb2256 Infineon Technologies Corporation, peb2256 Datasheet - Page 315

no-image

peb2256

Manufacturer Part Number
peb2256
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb2256H
Manufacturer:
Infineon
Quantity:
5
Part Number:
peb2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb2256HV1.2
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2256HV1.2
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
peb2256HV1.2
Manufacturer:
XILINX
0
Part Number:
peb2256HV1.4
Manufacturer:
INFINEON
Quantity:
1 831
Part Number:
peb2256R V1.2
Quantity:
5 510
T400MS
AIS
LOS
RAR
RA
Data Sheet
Receive Time Out 400 ms
Only active if multiframing is enabled.
The
FRS0.LFA = 0 and is searching for the multiframing. This interrupt is
set to indicate that no multiframing was found within a time window of
400 ms after basic framing has been achieved. In multiframe
synchronous state this interrupt is not generated.
Alarm Indication Signal
This bit is set when an alarm indication signal is detected and bit
FRS0.AIS is set. It is set during alarm simulation.
If GCR.SCI is set high this interrupt status bit is set with every change
of state of FRS0.AIS.
Loss-of-Signal
This bit is set when a loss-of-signal alarm is detected in the received
bit stream and FRS0.LOS is set. It is set during alarm simulation.
If GCR.SCI is set high this interrupt status bit is set with every change
of state of FRS0.LOS.
Remote Alarm Recovery
Set if a remote alarm in TS0 is cleared and bit FRS0.RRA is reset. It
is set also after alarm simulation is finished and no remote alarm is
detected.
Remote Alarm
Set if a remote alarm in TS0 is detected and bit FRS0.RRA is set. It
is set during alarm simulation.
framer
has
found
315
the
doubleframes
(basic
FALC56 V1.2
E1 Registers
PEB 2256
2002-08-27
framing)

Related parts for peb2256