peb2256 Infineon Technologies Corporation, peb2256 Datasheet - Page 237

no-image

peb2256

Manufacturer Part Number
peb2256
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb2256H
Manufacturer:
Infineon
Quantity:
5
Part Number:
peb2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb2256HV1.2
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2256HV1.2
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
peb2256HV1.2
Manufacturer:
XILINX
0
Part Number:
peb2256HV1.4
Manufacturer:
INFINEON
Quantity:
1 831
Part Number:
peb2256R V1.2
Quantity:
5 510
XCO(10:8)
Transmit Control 1 (Read/Write)
Value after reset: 9C
XC1
XCO(7:0)
Data Sheet
XCO7
7
Transmit Offset
Initial value loaded into the transmit bit counter at the trigger edge of
SCLKX when the synchronous pulse on port SYPX/XMFS is active
Refer to register XC1.
A write access to this address resets the transmit elastic buffer to its
basic starting position. Therefore, updating the value should only be
done when the FALC56 is initialized or when the buffer should be
centered. As a consequence a transmit slip will occur.
Transmit Offset
Calculation of delay time T (SCLKX cycles) depends on the value X
of the “Transmit Offset” register XC(1:0):
0 ≤ T ≤ 4: X = 4 - T
5 ≤ T ≤ maximum delay: X = 256 × SC/SD - T + 4)
with maximum delay = (256 × SC/SD) -1
with SC = system clock defined by SIC1.SSC(1:0)
with SD = 2.048 MHz
Delay time T = time between beginning of time slot 0 (bit 0, channel
phase 0) at XDI/XSIG and the initial edge of SCLKX after SYPX/
XMFS goes active.
See
H
page 111
direction together with these bits the TSWM.TSA(8:4) bits must
be set to enable transmission to the remote end transparently
through the FALC56.
for further description.
237
XCO0
FALC56 V1.2
E1 Registers
0
PEB 2256
2002-08-27
(23)