8
8-2 Alarm Table
8-2 Alarm Table
8-3
If the Servo Drive detects an error, the Alarm Output (ALM) will turn ON, the power drive circuit in
the Servo Drive will turn OFF, and the alarm code will be displayed.
Precautions
for Correct Use
• Refer to Error Diagnosis Using the Displayed Alarm Codes on page 8-6 for
• Reset the alarm using one of the following methods. Remove the cause of
Note, however, that some alarms can only be cleared by recycling the power
(turn ON
• If you clear an alarm while the RUN Command Input (RUN) is turned ON,
appropriate alarm countermeasures.
the alarm first.
• Turn ON the Alarm Reset Input (RESET).
• Turn OFF the power supply, then turn it ON again.
• Reset the alarm on the Parameter Unit.
the Servo Drive will start operation as soon as the alarm is cleared, which
is dangerous. Be sure to turn OFF the RUN Command Input (RUN) before
clearing the alarm. If the RUN Command Input (RUN) is always ON, first
check safety sufficiently before clearing the alarm.
→ OFF → ON). Refer to the Alarms table on the next page.