R88A-CNG01R Omron, R88A-CNG01R Datasheet - Page 102

no-image

R88A-CNG01R

Manufacturer Part Number
R88A-CNG01R
Description
Encoder Connector ABS Motor
Manufacturer
Omron
Datasheet

Specifications of R88A-CNG01R

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
3
3-1 Servo Drive Specifications
3-1 Servo Drive Specifications
General Specifications
Note 1. The above items reflect individual evaluation testing. The results may differ under compound conditions.
Note 2. Never perform withstand-voltage or other megameter tests on the Servo Drive. Doing so may damage the
Note 3. Depending on the operating conditions, some Servo Drive parts will require maintenance. Refer to 8-5
Note 4. The service life of the Servo Drive is 28,000 hours at an average ambient temperature of 55°C at 100%
3-1
Ambient operating temperature
and operating humidity
Ambient storage temperature
and storage humidity
Storage and operating
atmosphere
Vibration resistance
Impact resistance
Insulation resistance
Dielectric strength
Protective structure
Interna-
tional
standards
internal elements.
Periodic Maintenance on page 8-21.
of the rated torque.
EC
Direc-
tives
UL standards
CSA standards
Select the Servo Drive matching the Servomotor to be used. (For details, refer to Servo Drive-
Servomotor Combinations on page 2-5.)
The same OMNUC G-Series Servo Drive can be used for either a pulse string input or analog input.
You can change the control mode according to the Controller. (The default setting is for position
control with pulse string commands.)
Item
EMC
Directive
Low-
voltage
Directive
−20 to 65°C, 90% RH max. (with no condensation)
No corrosive gasses
Smaller of either 10 to 60 Hz with double amplitude of 0.1 mm or acceleration of
5.88 m/s
Acceleration of 19.6 m/s
Between power supply/power line terminals and frame ground: 0.5 MΩ. min.
(at 500 VDC)
Between power supply/power line terminals and frame ground: 1,500 VAC for 1 min
at 50/60 Hz
Between each control signal and frame ground: 500 VAC for 1 min
Built into panel (IP10).
EN 55011 class A group 1
EN 61000-6-2, IEC 61000-4-2/-3/-4/-5/-6/-11
EN 50178
UL 508C
CSA 22.2 No.14
0 to 55°C, 90% RH max. (with no condensation)
2
max. in X, Y, and Z directions.
2
max. 2 times each in X, Y, and Z directions
Specifications