Setting range
Setting range
Pn0A
Pn0B
Explanation of Settings
Explanation of Settings
• Use this parameter to assign the function of General-purpose Output 1 (OUTM1: CN1 pin 12).
• Use this parameter to set the operating method for the 17-bit absolute encoder.
• The setting of this parameter is disabled if a 5-core 2,500-pulse/revolution incremental encoder is
used.
General-purpose Output 1 Selection
Operation Switch When Using Absolute Encoder
Setting
Setting
0
1
2
3
4
5
6
7
8
0
1
2
0 to 8
0 to 2
Output during torque limit
Zero speed detection output
Warning output for over regeneration, overload, absolute encoder battery, or fan lock
Over regeneration warning output
Overload warning output
Absolute encoder battery warning output
Fan lock warning output
Reserved
Speed conformity output
Use as absolute encoder.
Use as incremental encoder.
Use as absolute encoder but ignore multi-turn counter overflow.
Unit
Unit
---
---
Explanation
Explanation
Default setting
Default setting
5-16 User Parameters
0
1
Power OFF→ON
Power OFF→ON
All modes
All modes
5-56
Yes
---