Table 9-13. RXP CPU Header Descriptor – 2
Table 9-14. RXP CPU Header Descriptor – 3
The RXP Local Timestamp may be used by the CPU for OAM Timestamp purposes (not for clock recovery).
RXP CPU Packets are first stored in the SDRAM RXP CPU Queue. The CPU controls the transfer of each RXP
CPU packet to an internal staging RXP CPU FIFO that the CPU can read from. The FIFO holds one RXP CPU
Packet at a time. The RXP CPU Queue can hold up to 512 packets (each 2Kbyte slot of the RXP CPU Queue is
reserved for one packet).
19-4750; Rev 1; 07/11
Field
RSVD
RXIPV6
RXIPV4
RXMO
RXIVO
RXMLC
RXLSF
RXDF
RSVD
RXL2TP [20]
RX2VT
RXVT
RXUDP
RXIP
RXMEF
RXMPLS [14]
RSVD
RXMLE
RXUEDA [9]
RXCET
RXOVO
RXUPW
RXUUP
RXUIPP [4]
RXRARP [3]
RXUET
RXUIPA [1]
RXUARP [0]
Field
RXLTS
Bit [x:y] Description
[31:30]
[29]
[28]
[27]
[26]
[25:24]
[23]
[22]
[21]
[19]
[18]
[17]
[16]
[15]
[13:11]
[10]
[8]
[7]
[6]
[5]
[2]
Bit [x:y] Description
[31:0]
Reserved.
RXP IPv6 packet. 1 = IPv6 Header; 0 = not IPv6.
RXP IPv4 packet. 1 = IPv4 Header; 0 = not IPv4.
RXP MEF OAM packet. 1 = MEF OAM Header; 0 = not MEF OAM.
RXP In-band VCCV OAM packet. 1 = In-band VCCV Header; 0 = not In-band VCCV.
RXP MPLS Label Count. 1 = number of outer MPLS labels.
RXP LLC/SNAP Format. 1 = IEEE 802.2 LLC/SNAP Header; 0 = not LLC/SNAP.
RXP DIX Format. 1 = DIX Header; 0 = not DIX.
Reserved.
RXP L2TPv3 packet. 1 = L2TPv3 Header; 0 = not L2TPv3.
RXP 2 VLAN Tagged packet. 1 = 2 VLAN tags in header; 0 = does not have 2 tags.
RXP VLAN Tagged packet. 1 = 1 or 2 VLAN tags in header; 0 = no VLAN tags.
RXP UDP packet. 1 = UDP Header; 0 = not UDP.
RXP IP packet. 1 = IPv4 or IPv6 Header; 0 = not IPv4 or IPv6.
RXP MEF packet. 1 = MEF Header; 0 = not MEF.
RXP MPLS packet. 1 = MPLS Header; 0 = not MPLS.
Reserved.
RXP MPLS Label Error. 1 = more than 3 MPLS labels; 0 = not more than 3 labels.
RXP Unknown Ethernet DA. 1 = unknown Ethernet DA; 0 = recognized Ethernet DA.
RXP CPU Ethernet Type. 1 = “CPU Destination” Ethernet Type.
RXP Out-band VCCV OAM. 1 = Out-band VCCV Header (matches OAM BID).
RXP Unknown PW. 1 = packet with a PW Header Type but with unknown PW-ID.
RXP Unknown UDP Protocol. 1 = UDP with unknown UDP protocol.
RXP Unknown IP Protocol. 1 = IP with unknown IP protocol.
RXP Recognized ARP packet. 1 = ARP Ethernet Type with recognized IP DA.
RXP Unknown Ethernet Type. 1 = unknown Ethernet Type
RXP Unknown IP DA. 1 = IP with unknown DA
RXP Unknown ARP packet. 1 = ARP Ethernet Type with unknown IP DA.
RXP Local Timestamp. 32-bit Timestamp with 100 us or 1 us resolution (G.GCR.OTRS),
latched at the time the packet is received by the Packet Classifier.
nd
rd
Dword
Dword
DS34S132 DATA SHEET