FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 345

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
FX Series Programmable Controllers
Points of interest:
a) Users of the IST instruction will be aware that only one of the operation modes should be
b) For users who would like to test this example using simulator switches (i.e., without using
c) Special flags used in this program are:
• M8040: State transfer inhibit
• M8041: State transfer start
• M8042: Start pulse
• M8043: Zero return complete
• M8044: At Zero position/ condition
active at one time. In this example program the isolation of ’Manual’ and ’Zero return’
modes by the use of separate DU control screens, and the use of a rotary switch to
isolate the three automatic modes achieves this objective. Alternatively all of the
operation modes could be selected by a rotary switch.
a data access unit) the appropriate program changes are noted next to the full program
listing later in this section. Alternatively, the original program could be used with all of the
input conditions being given by forcing ON the contacts with a programming device e.g.
a hand held programmer, Medoc etc.
- Manual mode: Always ON.
- Manual and Zero return modes: This flag is not used.
- This is momentarily active after the 'Start' input is received.
- This is a user activated device which should be controlled within the users program.
- This is a user activated device which should be controlled within the users program.
Zero return and Cycle modes: Once the 'Stop' input is given the current state is
retained until the 'Start' input is received.
Step mode: This flag is OFF when the 'Start' input is ON. At all other times M8040 is
ON, this enables the single STL step operation to be achieved.
Auto mode: M8040 is ON initially when the PLC is switched into RUN. It is reset
when the 'Start' input is given.
Step and Cycle modes: This flag is only active while the 'Start' input is received.
Auto mode: The flag is set ON after the 'Start' input is received. It is reset after the
'Stop' input is received.
Points Of Technique 10
10-13