FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 272

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
5.16
FX Series Programmable Controlers
Inline Comparisons - FNC 220 to FNC 249
Contents:
LD -
AND -
OR -
Symbols list:
D - Destination device.
S - Source device.
m, n- Number of active devices, bits or an operational constant.
Additional numeric suffixes will be attached if there are more than one operand with the same
function e.g. D
MSB - Most Significant Bit, sometimes used to indicate the mathematical sign of a number,
i.e. positive = 0, and negative = 1.
LSB - Least Significant Bit.
Instruction modifications:
D
D
- An operand which cannot be indexed, i.e. The addition of V or Z is either invalid or will
- A repetitive instruction which will change the destination value on every scan unless
modified by the pulse function.
have no effect to the value of the operand.
P -
-
-
-
An instruction operating in 16 bit mode, where
mnemonic.
A 16 bit mode instruction modified to use pulse (single) operation.
An instruction modified to operate in 32 bit operation.
A 32 bit mode instruction modified to use pulse (single) operation.
1
, S
LoaD compare
AND compare
OR compare
3
or for lists/tabled devices D
3+0,
FNC 224 to 230
FNC 232 to 238
FNC 240 to 246
S
+9
etc.
identifies the instruction
Applied Instructions 5
5-150
Page
5-152
5-153
5-151