FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 220

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
5.9.3
FX Series Programmable Controlers
ASCI (FNC 82)
Points to note:
Please note that data is converted ‘as read’, i.e. using the example above with the following
data in (D9,D8) ABCD
(in this case n= 6) and converting them to ASCI will store values in 6 consecutive bytes from
D20, i.e. D20 = (67, 68), D21 = (69, 70) and D22 = (50, 54) respectively. In true characters
symbols that would be read as CDEF26.
This can be shown graphically as in the table
to the right. Please take special note that the
source data (S) read from the most significant
device to the least significant. While the
destination data (D) is read in the opposite
direction.
The ASCI instruction can be used with the
M8161, 8 bit/16bit mode flag. The effect of this
flag is exactly the same as that detailed on
page 10-20. The example to the right shows
the effect when M8161 is OFF.
If M8161 was set ON, then only the lower
destination byte (b0-7) would be used to store data and hence 6 data registers would be
required (D20 through D25).
ASCII Character Codes
The table below identifies the usable hexadecimal digits and their associated ASCII codes
ASCI
FNC 82
(Converts
HEX to
ASCII)
ASCII
Code
Mnemonic
Character
Character
Symbol
HEX
DEC 48
HEX 30
Converts a data
value from
hexadecimal to
ASCII
’0’
0
Function
31
49
’1’
1
H
,EF26
32
50
’2’
2
33
51
’3’
3
H
. Taking the first n hexadecimal characters (digits) from the right
K, H, KnX,
KnY,
KnM, KnS
T, C, D, V, Z
34
52
’4’
4
35
53
’5’
S
5
36
54
’6’
6
Operation:
Th is i ns tru c tio n re a d s n h e xa d ec im a l da ta
characters from head source address (S) and
converts them in to the equivalent ASCII code.
This is then stored at the destination (D) for n
number of bytes.
KnY, KnM,
KnS
T, C, D
37
55
’7’
7
Operands
Source (S) Data
D9
D8
38
56
’8’
8
D
b12-15
b8-11
b4-7
b0-3
b12-15
b8-11
b4-7
b0-3
39
57
’9’
9
A
B
C
D
E
F
2
6
41
65
’A’
K, H
Note:
n = 1 to 256
A
42
66
’B’
B
Destination
D20
D21
D22
n
(D)
’C’
43
67
C
b8-15
b0-7
b8-15
b0-7
b8-15
b0-7
Applied Instructions 5
’D’
44
68
D
ASCI,
ASCIP:
7 steps
ASCII Code
HEX DEC
Program steps
43
44
45
46
32
36
5-98
45
69
’E’
E
67
68
69
70
50
54
46
70
’F’
F
Symbol
’C’
’D’
’E’
’F’
’2’
’6’

Related parts for FX1S-30MR-ES/UL