FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 199

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
5.7.10
FX Series Programmable Controlers
SORT (FNC 69)
records integrity. The resulting (new) data table is stored from destination device D.
Points to note:
a) When a sort occurs each record is sorted in to ascending order based on the data in the
b) The source (S) and destination (D) areas can be the same BUT if the areas are chosen to
c) Once the SORT operation has been completed the ‘Operation Complete Flag’ M8029 is
d) During a SORT operation, the data in the SORT table must not be changed. If the data is
e) The SORT instruction may only be used ONCE in a program.
From the example instruction and the ‘data table’ below left, the following data manipulation
will occur when nis set to the identified field
(m
SORT
FNC 69
(SORT
Tabulated
Data)
R
E
C
O
R
D
Mnemonic
1
selected sort field n.
be different, there should be no overlap between the areas occupied by the tables.
turned ON. For the complete sort of a data table the SORT instruction will be processed
m1times.
changed, this may result in an incorrectly sorted table.
)
1
2
3
4
(D100)
(D101)
(D102)
(D103)
Original
100
32
74
1
7
FIELD (m2)
Data in a defined
table can be
sorted on selected
fields while
retaining record
integrity
(D104)
(D105)
(D106)
(D107)
162
80
34
2
6
Function
(D108)
(D109)
(D110)
(D111)
200
62
3
4
6
Table1st table sort when n= 2
(m
O
R
E
C
R
D
D
1
)
S
1
2
3
4
(D100)
(D101)
(D102)
(D103)
100
K, H
Note:
m1= 1 to 32
m2= 1 to 6
74
32
1
7
Operation:
This instruction constructs a data table of m
records with m
address of S. Then the data in field nis sorted in to
numerical order while retaining each individual
m
FIELD (m2)
1
(D104)
(D105)
(D106)
(D107)
162
34
80
2
6
Operands
m
(D108)
(D109)
(D110)
(D111)
200
2
62
3
6
4
D
2
D
fields having a start or head
(m
2nd table sort when n=1
R
E
C
O
R
D
1
)
K, H
D
Note:
n = 1 to
m2
1
2
3
4
n
(D100)
(D101)
(D102)
(D103)
100
Applied Instructions 5
32
74
1
7
SORT:
11 steps
FIELD (m2)
Program steps
(D104)
(D105)
(D106)
(D107)
162
5-77
34
80
2
6
(D108)
(D109)
(D110)
(D111)
200
62
3
6
4
1