FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 283

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
6.4
FX Series Programmable Controller
PLC Operation Mode
(M8030 to M8039 and D8030 to D8039)
For symbol key see page 6-1.
M8030 ( )
Battery LED
OFF
(Not FX
FX
M8031 ( )
Non-latch
memory all
clear
M8032 ( )
Latch memory
all clear
M8033 ( )
Memory hold
in ‘stop’ mode
M8034 ( )
All outputs
disable
M8035 ( S)
Forced
operation
mode
M8036 ( S)
Forced RUN
signal
M8037 ( S)
Forced STOP
signal
M8038( )
N to N
networking
M8039 ( )
Constant
scan mode
Diagnostic
1N
Device
)
1S
,
Battery voltage is low but
BATT.V LED not lit
Current device settings are
reset at next END, i.e. con-
tacts, coils and current data
values for Y, M, S, T, C and
D devices respectively. Spe-
cial devices which have
default settings are
refreshed with those defaults
The device statuses and set-
tings are retained when the
PLC changes from RUN to
STOP and back into RUN
All of the physical switch
gear for activating outputs is
disabled. However, the pro-
gram still operates normally.
By using forced operation
mode, i.e.M8035 is turned
ON, it is possible to perform
remote RUN/STOP or
pulsed RUN/ STOP opera-
tion.
Please see Chapter 10 for
example operation
For the setting of devices
when using an N to N
network
When ON the PLC executes
the user program within a
constant scan duration. The
difference between the
actual end of the program
operation and the set con-
stant scan duration causes
the PLC to ‘pause’.
Operation
D8030 ( )
(FX
only)
D8031 ( )
(FX
only)
D8032 -D8038 Reserved
D8039 ( )
Constant
scan duration
Diagnostic
1S
1S
Device
& FX
& FX
1N
1N
Value read from first setting
“pot” in msec, (0 to 255)
Value read from second set-
ting “pot” in msec, (0 to 255)
This register can be written to
by the user to define the dura-
tion of the constant scan. Res-
olutions of 1msec are
possible.
This register has a default set-
ting 0 msec which will be initi-
ated during power ON.
Diagnostic Devices 6
Operation
6-5