HD6413008F RENESAS [Renesas Technology Corp], HD6413008F Datasheet - Page 448

no-image

HD6413008F

Manufacturer Part Number
HD6413008F
Description
Renesas 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413008F25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008F25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6413008F25V
Manufacturer:
MITSUMI
Quantity:
2 949
Part Number:
HD6413008F25V
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6413008F25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6413008FBL25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008FBL25
Manufacturer:
HIT
Quantity:
9 676
13. Smart Card Interface
Interrupt Operations: The smart card interface has three interrupt sources: transmit-data-empty
(TXI), transmit/receive-error (ERI), and receive-data-full (RXI). The transmit-end interrupt
request (TEI) is not available in smart card mode.
A TXI interrupt is requested when the TEND flag is set to 1 in SSR. An RXI interrupt is requested
when the RDRF flag is set to 1 in SSR. An ERI interrupt is requested when the ORER, PER, or
ERS flag is set to 1 in SSR. These relationships are shown in table 13.8.
Table 13.8 Smart Card Interface Mode Operating States and Interrupt Sources
Operating State
Transmit Mode
Receive Mode
Examples of Operation in GSM Mode: When switching between smart card interface mode and
software standby mode, use the following procedures to maintain the clock duty cycle.
• Switching from smart card interface mode to software standby mode
1. Set the P9
2. Write 0 in the TE and RE bits in the serial control register (SCR) to stop transmit/receive
3. Write 0 in the CKE0 bit in SCR to stop the clock.
4. Wait for one serial clock cycle. During this period, the duty cycle is preserved and clock output
5. Write H'00 in the serial mode register (SMR) and smart card mode register (SCMR).
6. Make the transition to the software standby state.
• Returning from software standby mode to smart card interface mode
1'. Clear the software standby state.
2'. Set the CKE1 bit in SCR to the value for the fixed output state at the start of software standby
3'. Set smart card interface mode and output the clock. Clock signal generation is started with the
Rev.4.00 Aug. 20, 2007 Page 404 of 638
REJ09B0395-0400
output state in software standby mode.
operations. At the same time, set the CKE1 bit to the value for the fixed output state in
software standby mode.
is fixed at the specified level.
(the current P9
normal duty cycle.
4
data register (DR) and data direction register (DDR) to the values for the fixed
4
pin state).
Normal operation
Error
Normal operation
Error
Flag
TEND
ERS
RDRF
PER, ORER
Enable Bit
TIE
RIE
RIE
RIE
Interrupt Source
TXI
ERI
RXI
ERI

Related parts for HD6413008F