HD6413008F RENESAS [Renesas Technology Corp], HD6413008F Datasheet - Page 234

no-image

HD6413008F

Manufacturer Part Number
HD6413008F
Description
Renesas 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413008F25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008F25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6413008F25V
Manufacturer:
MITSUMI
Quantity:
2 949
Part Number:
HD6413008F25V
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6413008F25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6413008FBL25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008FBL25
Manufacturer:
HIT
Quantity:
9 676
8. 16-Bit Timer
Bit 6—Input Capture/Compare Match Interrupt Enable A2 (IMIEA2): Enables or disables
the interrupt requested by the IMFA2 when IMFA2 flag is set to 1.
Bit 6
IMIEA2
0
1
Bit 5—Input Capture/Compare Match Interrupt Enable A1 (IMIEA1): Enables or disables
the interrupt requested by the IMFA1 flag when IMFA1 is set to 1.
Bit 5
IMIEA1
0
1
Bit 4—Input Capture/Compare Match Interrupt Enable A0 (IMIEA0): Enables or disables
the interrupt requested by the IMFA0 flag when IMFA0 is set to 1.
Bit 4
IMIEA0
0
1
Bit 3—Reserved: This bit cannot be modified and is always read as 1.
Bit 2—Input Capture/Compare Match Flag A2 (IMFA2): This status flag indicates GRA2
compare match or input capture events.
Bit 2
IMFA2
0
1
Rev.4.00 Aug. 20, 2007 Page 190 of 638
REJ09B0395-0400
Description
IMIA2 interrupt requested by IMFA2 flag is disabled
IMIA2 interrupt requested by IMFA2 flag is enabled
Description
IMIA1 interrupt requested by IMFA1 flag is disabled
IMIA1 interrupt requested by IMFA1 flag is enabled
Description
IMIA0 interrupt requested by IMFA0 flag is disabled
IMIA0 interrupt requested by IMFA0 flag is enabled
Description
[Clearing condition]
Read IMFA2 flag when IMFA2 = 1, then write 0 in IMFA2 flag
[Setting conditions]
16TCNT2 = GRA2 when GRA2 functions as an output compare register
16TCNT2 value is transferred to GRA2 by an input capture signal when GRA2
functions as an input capture register
(Initial value)
(Initial value)
(Initial value)
(Initial value)