r4f2456 Renesas Electronics Corporation., r4f2456 Datasheet - Page 905

no-image

r4f2456

Manufacturer Part Number
r4f2456
Description
16-bit Single-chip Microcomputer H8s Family / H8s/2400 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
r4f24565NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24565NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24568NVFQV
Manufacturer:
REA
Quantity:
15
Part Number:
r4f24568NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24568NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24568NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24568NVZFQV
Manufacturer:
REA
Quantity:
5
Part Number:
r4f24568NVZFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24569DVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24569DVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24569VFQV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
No
No
No
Figure 15.13 Sample Multiprocessor Serial Reception Flowchart (1)
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Set MPIE bit in SCR to 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read RDRF flag in SSR
FER ∨ ORER = 1?
FER ∨ ORER = 1?
All data received?
Start of reception
This station's ID?
Initialization
RDRF = 1?
RDRF = 1?
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
[4]
[3]
[1]
[2]
Error handling
(Continued on
next page)
Section 15 Serial Communication Interface (SCI, IrDA)
[5]
[1]
[2]
[3]
[4]
[5]
Rev. 1.00 Sep. 19, 2008 Page 875 of 1342
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception
and comparison:
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station’s ID.
If the data is not this station’s ID,
set the MPIE bit to 1 again, and
clear the RDRF flag to 0.
If the data is this station’s ID,
clear the RDRF flag to 0.
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
Receive error handling and break
detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After
performing the appropriate error
handling, ensure that the ORER
and FER flags are both cleared
to 0.
Reception cannot be resumed if
either of these flags is set to 1.
In the case of a framing error, a
break can be detected by reading
the RxD pin value.
REJ09B0467-0100

Related parts for r4f2456