r4f2456 Renesas Electronics Corporation., r4f2456 Datasheet - Page 872

no-image

r4f2456

Manufacturer Part Number
r4f2456
Description
16-bit Single-chip Microcomputer H8s Family / H8s/2400 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
r4f24565NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24565NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24568NVFQV
Manufacturer:
REA
Quantity:
15
Part Number:
r4f24568NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24568NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24568NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24568NVZFQV
Manufacturer:
REA
Quantity:
5
Part Number:
r4f24568NVZFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24569DVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24569DVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24569VFQV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 15 Serial Communication Interface (SCI, IrDA)
Rev. 1.00 Sep. 19, 2008 Page 842 of 1342
REJ09B0467-0100
Bit
4
3
Bit Name
FER
PER
Initial Value
0
0
R/W
R/(W) *
R/(W) *
Description
Framing Error
Indicates that a framing error occurred while
receiving in asynchronous mode and the reception
has ended abnormally.
[Setting condition]
[Clearing condition]
Parity Error
Indicates that a parity error occurred while
receiving in asynchronous mode and the reception
has ended abnormally.
[Setting condition]
[Clearing condition]
In 2-stop-bit mode, only the first stop bit is
checked for a value of 0; the second stop bit is
not checked. If a framing error occurs, the
receive data is transferred to RDR but the
RDRF flag is not set. Also, subsequent serial
reception cannot be continued while the FER
flag is set to 1. In clocked synchronous mode,
serial transmission cannot be continued,
either.
1
The FER flag is not affected and retains its
previous state when the RE bit in SCR is
cleared to 0.
reception
If a parity error occurs, the receive data is
transferred to RDR but the RDRF flag is not
set. Also, subsequent serial reception cannot
be continued while the PER flag is set to 1. In
clocked synchronous mode, serial
transmission cannot be continued, either.
1
The PER flag is not affected and retains its
previous state when the RE bit in SCR is
cleared to 0.
When the stop bit is 0
When 0 is written to FER after reading FER =
When a parity error is detected during
When 0 is written to PER after reading PER =