PEB 4364 T V1.2 Infineon Technologies, PEB 4364 T V1.2 Datasheet - Page 177

no-image

PEB 4364 T V1.2

Manufacturer Part Number
PEB 4364 T V1.2
Description
IC SLIC VOICE ACCESS PDSO-36
Manufacturer
Infineon Technologies
Series
DuSLICr
Datasheet

Specifications of PEB 4364 T V1.2

Function
Dual Channel Subscriber Line Interface Circuit (DuSLIC)
Interface
IOM-2, PCM
Number Of Circuits
2
Voltage - Supply
3.3 V ~ 5 V
Current - Supply
105mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
36-PDSO
Includes
DTMF Generator and Decoder, Line Echo Cancellation (LEC), Teletax (TTX) Generation, Universal Tone Detection (UTD)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB4364TV1.2XT
SP000007728
Bit
UTDR-EN
UTDX-EN
CIS-AUTO
CIS-EN
Preliminary Data Sheet
19
H
BCR5
UTDR-
EN
7
Enables the Universal Tone detection in receive direction.
UTDR-EN = 0 Universal Tone detection is disabled.
UTDR-EN = 1 Universal Tone detection is enabled.
Enables the Universal Tone detection in transmit direction.
UTDX-EN = 0 Universal Tone detection is disabled.
UTDX-EN = 1 Universal Tone detection is enabled.
Controls the turn-off behavior of the Caller ID sender.
CIS-AUTO = 0 The Caller ID sender stops when CIS-EN is switched to 0.
CIS-AUTO = 1 The Caller ID sender continues sending data until the
Enables the Caller ID sender in the SLICOFI-2.
Note: The Caller ID sender is configured directly by programming the
CIS-EN = 0
CIS-EN = 1
UTDX-
according POP registers. Caller ID data are written to a 48 byte
RAM buffer. According to the buffer request size, this influences the
CIS-REQ and CIS-BUF bits.
EN
6
Basic Configuration Register 5
AUTO
data buffer is empty.
cleared after all data are sent or if CIS-AUTO = 0.
written to the data buffer. After the last data bit is sent,
stop bits are sent to the subscriber.
Caller ID data are sent to the subscriber when the number
of bytes written to the buffer exceeds CIS-BRS + 2.
Caller ID sender is disabled and Caller ID data buffer is
Caller ID sender is enabled and Caller ID data can be
CIS-
5
CIS-EN
4
177
LEC-
OUT
3
LEC-EN DTMF-
2
00
H
SRC
1
DS3, 2003-07-11
DuSLIC
DTMF-
EN
0
Y

Related parts for PEB 4364 T V1.2