3F88L-CR002C Omron, 3F88L-CR002C Datasheet - Page 95

no-image

3F88L-CR002C

Manufacturer Part Number
3F88L-CR002C
Description
CABLE RESOLVER FOR RS17/T 2M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CR002C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCR002C
Operation
H Control Outputs
Origin shift input
Reset input
RUN output
Resolver rotation
detection output
Error output
Name
Name
TRIG
RESET
RUN
M-DET
ERROR
Symbol
Symbol
When the origin shift input is turned from OFF to ON in RUN mode,
origin shift is executed.
Note
Note
Note
Note
Regardless of the current operation mode, hardware reset is performed
when the reset input is turned ON and the system will return to the
startup status.
Note
Note
ON: Cam outputs enabled
OFF: Cam outputs disabled
In any of the following circumstances, cam outputs will be enabled if no
errors have been generated.
• When the START signal is ON in RUN mode (including during compensa-
• When the trial operation function is started in PRGM mode.
Cam outputs will be disabled under any of the following circumstances.
• When the START signal is OFF in RUN mode.
• When an error has been generated (error code E--** or a watchdog error).
• When changing from RUN to PRGM mode or from RUN to SET mode.
• When the trial operation function is completed in PRGM mode.
Note Refer to 7-2 Performance for information on ON and OFF delay
ON: When Resolver speed is 4 r/min or greater
OFF: When Resolver speed is less than 4 r/min or an error has been
generated. (Refer to 5-1 Diagnosis using Error Codes.)
Note Refer to 7-2 Performance for information on ON and OFF delay
ON: While error code E--** or watchdog errors have not been generated.
OFF: When an error code E--** or watchdog error has been generated
(Refer to 5-1 Diagnosis using Error Codes). Alternatively, during
initialization when the power is turned ON. (Refer to 7-2 Performance
for information on initialization times.)
tion operation)
(Refer to 5-1 Diagnosis using Error Codes.)
times for RUN outputs.
times when the Resolver speed is 4 r/min or greater.
1. TRIG input is ignored when the Unit is in modes other than RUN.
2. TRIG input is disabled when Resolver speed is 4 r/min or great-
3. The TRIG signal is enabled when it has been turned ON for
4. Refer to 7-2 Performance for information on the relationship be-
1. All outputs will turn OFF, regardless of the output hold settings.
2. The origin values retained for origin shift will be lost.
er.
10 ms or longer.
tween TRIG inputs, RUN outputs, and cam outputs.
Function
Function
Chapter 3
3-43