Operation
3-96
Other Keys
Operation
CAM/
PRMTR
SET
SET
Display
Press the Set Key to save the adjusted angle data and display step 2.
Use the same procedure to adjust the ON and OFF angles for step 2
onwards.
Note
Note
Press the Cam/Parameter Key to adjust other cam numbers.
The display will return to a flashing cam number.
Repeat the same operation to adjust the angles for each step in other
cam numbers.
Use the Up and Down Keys to set the cam number, use the Set Key to
display the ON and OFF angle data, use the Up and Down Keys to
adjust the ON angle data, use the ON/OFF Switching Key to make the
OFF angle flash, use the Up and Down Keys to adjust the OFF angle,
and use the Set Key to save the adjusted data. Repeat this operation
as required.)
To exit the adjustment operation function, press any key other than the
Up, Down, or Set Keys while the cam number is flashing.
The display will exit the adjustment operation function and return to
normal RUN mode.
1. The display will not move on to step 2 if there is only one step.
2. During adjustment operation, the data changes will be re-
flected in the outputs and cam program at the point the
changes are made.
Explanation
Chapter 3