7-18
E-12
E-13
E-22
E-23
Error
code
System
program sum
check error
Memory error
Cam data
protect input
prohibited
Cam program
duplication
error
Error name
System
program sum
check error
when power
turned ON.
Access to
non-volatile
memory not
completed
within set time.
Attempt made
to edit
cam-protected
cam data.
Attempt made
to write
program to the
ON section of
an existing
program
(including
attempt with
the teaching
function)
Description
F
f
f
f
output
Cam
Malfunction
due to noise
(system
recovers when
power is
turned ON
again.)
The Cam
Positioner is
malfunctioning
(system does
not recover
when power is
turned ON
again.)
Write to
non-volatile
memory not
completed due
to noise.
Read from
non-volatile
memory not
completed due
to noise.
Attempt made
to edit
cam-protected
cam data.
Attempt made
to write
program to the
ON section of
an existing
program
(including
attempt with
the teaching
function)
Probable
cause
Check if noise
occurs when or after
the power is turned
ON and take
appropriate
countermeasures
against the noise.
Replace the Cam
Positioner.
Find the source of
the error and take
appropriate
countermeasures.
Find the source of
the error and take
appropriate
countermeasures.
Once the error has
been cleared, either
remove the cam data
protect, or edit
different cam data
that has not been
cam data protected.
Once the error has
been cleared, write
the correct steps that
are not duplicated.
Possible solution
Chapter 7
Turn ON the
power again.
---
Change to
PRGM or SET
mode and
press the
Clear Key to
clear the error.
Press the
Clear Key to
clear the error.
Press the
Clear Key to
clear the error.
Error reset
method
y