3F88L-CR002C Omron, 3F88L-CR002C Datasheet - Page 16

no-image

3F88L-CR002C

Manufacturer Part Number
3F88L-CR002C
Description
CABLE RESOLVER FOR RS17/T 2M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CR002C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCR002C
Outline
H Output Hold Function
• Holds the immediately preceding cam output status when the user switches to PRGM mode or when
H Present Value Output Function
• Uses the cam output signal and outputs the signal to the Display Unit (M7E, M7F, or other Display
H Pulse Output Function
• Automatically sets data that turns ON and OFF at regular intervals in a desired bank or cam in order to
H Teaching
• The Resolver angle data may be input as cam program settings during manual operation of the
H Copy Function
• By making the settings for one Cam Positioner, the cam program, the various compensation values,
H Trial Operation
• When adjusting the ON/OFF angles to suit the machinery, performs cam output and changes the ON/
H Compensation Operation
• When adjusting the ON/OFF angles to suit the machinery, changes the ON/OFF angles in real time
H Communications Function
• Has a communications port that conforms to shape B in CompoWay/F. Communications can be used
Note CompoWay/F is a uniform procedure in OMRON serial communications. CompoWay/F has uni-
there is an error. (Refer to 3-6-9 Output Hold Function.)
Units.) The present angle or number of revolutions can be displayed on the Display Unit. (Refer to
3-6-10 Present Value Output Function.)
edit memory contents. (Refer to 3-6-11 Pulse Output Function.)
machinery. (Refer to 3-6-12 Teaching.)
and settings in one operation may be copied to another Cam Positioner.
OFF angle in real time regardless of the control input signal status. (Refer to 3-6-14 Trial/Adjustment
Operation.)
while in operation status (cam output status). (Refer to 3-6-14 Trial/Adjustment Operation.)
to read and write cam programs and monitor present angles and number of revolutions. (Refer to
Chapter 4 Communications.)
form frame formats and commands that conform to FINS (Factory Interface Network Service) that
is used in OMRON PCs. It facilitates easier communications between multiple components and
between personal computers and components.
Chapter 1
1-5