Operation
Check the data for all cam programs that have been created.
If there are errors in any cam program, follow the procedure outlined in the previous section and set the
correct data.
H Cam Program Deletion (PRGM Mode)
D Deleting by Steps
3-32
Operation
Operation
This section explains how to delete cam programs after they have been created or while
they are being created.
The four methods to delete cam programs are shown below. Each of these methods will
be explained in this section.
BANK/
FUN
S ON/OFF angle data deleted by steps.
S ON/OFF angle data deleted by cam numbers.
S ON/OFF angle data deleted by bank numbers.
S All cam programs deleted at once.
SET
SET
Display
Display
Check the data for step 3 in the same way.
Check data through to the last step.
Set the mode selection switch to PRGM mode.
The data for step 1 of the displayed bank and cam numbers
will be displayed.
Note If there is no data, the display will be “-- -- --.”
Press the Bank/Function Key and set the bank number that
contains the step to be deleted.
The Bank/Function display will change as shown below each
time the Bank/Function Key is pressed.
1→2→3→4→5→6→7→8→1 etc.
Keep pressing the Bank/Function Key until the bank number to
be set appears.
Note When the resolution is set to 720 (divisions/rotation), the
display will not include 5→6→7→8.
Explanation
Explanation
Chapter 3