Operation
3-92
S S S S Data Transfer between Different Cam Positioner Models
S S S S Operation after Data Transfer
S S S S Communications Errors
When data is transferred between 3F88L-160 and 3F88L-162 Cam Positioner Units, cam pro-
grams for cam numbers 17 to 32 will be transferred. However, if these programs have been
transferred to 3F88L-160 Cam Positioner Units, they cannot be displayed or checked. If data is
transferred to a 3F88L-162 Cam Positioner from a 3F88L-160 Cam Positioner that has cam pro-
grams for cam numbers 17 to 32, these cam programs can be checked on the 3F88L-162 Cam
Positioner side.
Once the data transfer has been completed, turn OFF the power for the Cam Positioner that re-
ceived the data transfer and then turn it ON again. The parameters will be enabled when the
power is turned ON again.
The power must be turned OFF and then ON again to determine if the data has been correctly
transferred.
The following communications errors may occur.
E-22 (Cam Protect Error)
This cam protect error will occur on the receiving side if there is a cam that has been cam pro-
tected in that Cam Positioner. The parameters will be transferred but the cam program will termi-
nate with an error. Clear all cam protects on the receiving Cam Positioner and then re-transfer
the data. (Refer to 3-6-7 Cam Protect.)
If the Cam Positioner transmitting the data is a Master Unit, an E-31 (communications error) will
be generated in the Master Unit.
E-31 (Communications Error)
This communications error is generated in the Master Unit when there has been no response
from the Slave Unit or when there has been a communications data error in the Slave Unit. If this
error occurs while data is transferred, transfer of some parameters or partial cam programs may
result.
Press the Clear Key to delete the error.
This error will not occur in the Slave Unit.
E-33 (Verification Error)
This verification error is generated when the cam programs or parameters on the Master Unit do
not match those on the Slave Unit.
Press the Clear Key to delete the error.
This error will not occur in the Slave Unit.