Operation
Note 1. The functions are enabled once the power has been turned OFF and then ON again.
Note 2. The display will change as shown below when the Bank/Function Key is pressed repeatedly
3-5-2 Initial Settings
H Rotation Direction Selection Setting
The CW/CCW setting switch is used to change the direction of rotation.
Set the direction of increasing angles to “CW” for clockwise direction when viewed from the Resolver
axis, and “CCW” for counterclockwise direction (as shown in the following diagram).
Note These settings will be enabled by turning the power supply OFF and then ON again.
If the resolution selection (explained in the next section) is set to “1” (720 divisions/rotation),
Operation
5→6→7→8
Only the rotation direction (CW/CCW selection switch) and resolution setting (SET
mode) are changed at function level 1.
to set the function number.
BANK/
FUN
SET
Function level 0: 1→2→3→4→5→6→7→8→U→1→etc.
Function level 1: 1→2→3→4→5→6→7→8→A→t→U→1→etc.
Function level 2: 1→2→3→4→5→6→7→8→A→b→C→d→F→H→P→t→U→1→etc.
” will not be displayed.
Display
Press the Set Key to confirm the settings.
The setting will stop flashing for approximately
1 second and then resume flashing.
Note When a setting is flashing, the Up and Down
Press the Bank/Function Key.
The display will return to only the function number that
appears.
Turn OFF the power supply. (The settings will now be
enabled.)
Keys are enabled and the setting may be
changed.
CW/CCW setting switch
Explanation
Chapter 3
3-21