Operation
Once a program has been checked for one cam number, change the cam number (using the Cam/Pa-
rameter Key) and check another cam program in the same way. If multiple bank numbers are used,
change the bank number (using the Bank/Function Key) and check another program in the same way.
D Cam Program Deletion (PRGM Mode)
There four methods to delete cam programs. Each of these methods will be explained in this section.
• ON/OFF angle data deleted by steps.
• ON/OFF angle data deleted by cam numbers.
• ON/OFF angle data deleted by bank numbers.
• All cam programs deleted at once.
Deleting by Step (PRGM Mode)
Deleting by Cam Number (PRGM Mode)
1
2
3
4
5
6
1
2
3
4
5
Operation
Operation
CLR
BANK/
FUN
BANK/
FUN
CAM/
PRMTR
CAM/
PRMTR
CLR
SET
SET
SET
CLR
Set the mode selection switch to PRGM mode.
Press the Bank/Function Key and set the bank number that contains
the step to be deleted.
Press the Cam/Parameter Key and set the cam number that contains
the step to be deleted.
Press the Set Key to display the step to be deleted.
Press the Clear Key once. (The ON angle and OFF angle displays will
start flashing.)
Press the Set Key to delete the step.
Set the mode selection switch to PRGM mode.
Press the Bank/Function Key and set the bank number that contains
the cam number to be deleted.
Press the Cam/Parameter Key and set the cam number that is to be
deleted.
Press the Clear Key twice. (The cam number display will start flashing.)
Press the Set Key to delete the cam number.
Explanation
Explanation
Chapter 3