Appendix
E-31
E-33
Error
code
Communica-
tions error
Verification
error
Error name
No response
from the Slave
Unit; commu-
nications data
error; different
baud rate to
Slave.
Slave and
Master data
do not match.
Description
diff
f
f
output
Cam
Different baud
rate to Slave
Unit.
Slave Unit not
operating.
Slave Unit
error.
Slave Unit not
in communica-
tions mode.
Communica-
tions cable
wired incor-
rectly.
Different
programs or
parameters
are verified.
Data corrupted
due to noise
during com-
munications.
Probable
cause
Align the Master and
Slave Unit baud
rates (Function No.
b, Parameter No. 6).
Check the display on
the Slave Unit
(Bank/Function
display: “t”;
Cam/Parameter
display: “0”) and
re-transmit the data
from the Master Unit.
Clear the errors on
both the Master and
Slave Units and
re-transmit the data.
Check the display on
the Slave Unit
(Bank/Function
display: “t”;
Cam/Parameter
display: “0”) and
re-transmit the data
from the Master Unit.
Check and adjust the
communications
cable wiring.
Check that the cam
program and
parameters are
correct for each Cam
Positioner.
Find the source of
the noise and take
appropriate
countermeasures.
Possible solution
Chapter 7
Press the
Clear Key to
clear the error.
Press the
Clear Key to
clear the error.
Error reset
method
7-19