Appendix
7-20
(Error
indica-
tor not
lit)
Error
code
Power OFF
watchdog
error
Error name
Power is not
turned ON;
RESET input
has been
turned ON;
software error
Description
F
output
Cam
Power has
turned OFF.
RESET input
has been
turned ON.
RESET input
has been
turned ON due
to noise.
The Cam
Positioner is
malfunctioning
(system does
not recover
when power is
turned ON
again.)
Probable
cause
Check that the
voltage supplied to
the Cam Positioner
meets the
specifications (85 to
264 V AC) and
adjust if necessary.
Adjust the RESET
input sequence.
Find the source of
the noise and take
appropriate
countermeasures.
Check and adjust the
wiring for control
input signals.
Replace the Cam
Positioner.
Possible solution
Chapter 7
Turn ON the
power again.
---
Error reset