Operation
3-5
3-5-1 Function Level Selection Setting (SET Mode)
H Function Level Selection Setting and Checking
Check if the function level is set to function level 1 (basic operation/monitor only). Change to function
level 1 (basic operation/monitor only) if set to a different level.
D Procedure
Set the function level selection to “1” (function level 1).
3-20
U (u)
Function
No.
Operation
Basic Operation
BANK/
FUN
SET
1
Parameter
No.
Function
level
selection
Function
Display
0 to 2
Setting
range
If the Cam Positioner power is turned ON while in RUN
mode, the display will appear as shown to the left.
• Bank/Function: Displays the bank number specified
• Cam/Parameter: (Clear)
• SPEED/ON angle display: Displays the Resolver
• POSITION/OFF: Displays the present angle.
Use the mode selection switch to change to SET
mode.
Keep pressing the Bank/Function Key until “U” appears
on the display.
Note The display will change from
Press the Set Key to allow settings to be made.
• Cam/Parameter number display: “1”
• SPEED/ON angle display: Flashes current setting
If the setting is not on “1,” use the Up or Down Key to
change to “1” (function level 1).
0: Function level 0
1: Function level 1
2: Function level 2
by the bank selection input (banks 1 to 3).
speed (r/min).
1→2→....→8→A→t→U→1→..
0: Function level 0 (monitor only)
1: Function level 1 (basic operation/monitor
2: Function level 2 (all functions)
only) (factory setting)
Explanation
Function level
Details
Chapter 3
0
1
2