Operation
D Origin Compensation Absolute Angle (Display)
• Use this parameter to display the origin compensation absolute angle (origin position after origin com-
• If the parameter number is “0,” the same numeric value will be displayed, regardless of the function
Note The numeric values for 720 (divisions/rotation) resolution are shown in parentheses.
Operation
H Origin Compensation Execution (SET Mode)
D Procedure
3-58
Function
No.
(Manual operation
of the machinery)
(After origin
compensation has
been completed)
pensation or origin shift for the Resolver’s electrical 0°) in the SPEED/ON display.
number (1 to 8 or 1 to 4).
Operation
1 to 8 (1 to 4)
(see note)
Origin compensation
absolute angle (display)
Use the mode selection switch to change to SET mode.
Display
Parameter
No.
Origin compensation
absolute angle (display)
0
Use the mode selection switch to change to SET mode.
Rotate the machinery to the position to be set to zero.
Press the ADJ switch. Origin compensation will be executed.
The absolute angle (electrical angle of the Resolver) will be
flashing in the POSITION/OFF display until origin
compensation has been completed.
The original display will appear when origin compensation has
been completed.
Note If the bank number appears in the Bank/Function display
Use the mode selection switch to change to RUN mode.
The speed display will be “0” and present angle will be “0” if the
machinery is not operating.
and “0” appears in the Cam/Parameter No. display, the
absolute angle for origin compensation will be displayed
in the SPEED/ON display.
Setting range (Display only)
Origin compensation
absolute angle (display)
Explanation
Function level
Chapter 3
0
1
2