Operation
Note
Note
Bank selection input
(BANK1 to 3)
(
Operation start input
(START)
Machinery operation
starts
Operation
1. To change the ON and OFF angles, follow the directions in 3-5-3 Cam Program Creating and Checking
2. Use the compensation operation function to change the angle data during operation. Refer to 3-6 Ap-
and change the angle data.
plied Functions for details.
)
Display
Use the control input bank selection input (BANK1 to 3) to
specify the bank number to be used.
Note Refer to 3-5-8 Control I/O Signals for information on the
Turn ON the operation start input signal (START) for control
input.
When cam output is enabled, the control output RUN output
signal (RUN) is turned ON.
Note When the operation start signal (START) is turned ON,
Start up the machinery and start operation.
Note Observe the movement of peripheral devices to check if
24 V DC
24 V DC
relationship between bank selection input (BANK1 to 3)
and execution bank numbers.
“ru” will appear in the Cam/Parameter No. display.
the cam output signals are being output at the correct
timing.
24V
Explanation
RUN
Set bank number
(BANK 1 to 3)
E.g.:To set bank No. 2:
BANK 1:ON
BANK 2: OFF
BANK 3: OFF
Turn ON the operation
start signal (START).
Chapter 3