Outline
1-3-1 Display Section
• Displays the operation status, error status, and settings data.
• The data displayed will differ depending on the mode.
1-3-2 Switches
1-8
1. Bank and function display
2. Cam and parameter
number display
3. Number of revolutions and
ON
ON angle display
4. Present angle and OFF
angle display
5. Mode selection switch
6. P ⋅ CLR switch
7. ADJ switch
8. CW/CCW setting switch
l di l
l di l
p y
Name
Name
g
p y
RUN
PRGM
SET
RUN
PRGM
SET
RUN
PRGM
SET
RUN
PRGM
SET
---
PRGM
SET
When power is turned ON
Mode
Mode
Display the number of the operating bank.
Display the number of the bank being programmed.
Display the number of the function being set.
Displays “ru” when the START signal is ON and is blank
when the START signal is OFF.
Displays the number of the cam being programmed.
(Different for different settings functions.)
Displays the number of revolutions or an error message.
Displays the ON angle or an error message.
(Differs for different settings functions.)
Displays the present angle.
Displays the OFF angle.
(Different for different settings functions.)
Switches between the three operation
modes: RUN, PRGM, and SET.
Deletes all cam programs in the Cam
Positioner.
Adjusts the compensation by executing
origin compensation.
Changes the rotation direction. The direc-
tion of increasing angle is set to either CW
(clockwise) or CCW (counterclockwise)
when viewed from the Resolver axle side.
Display
Function
Chapter 1