Specifications
6-1
H General Specifications
6-2
Power supply voltage
Allowable power
supply voltage
Current consumption
Inrush current
I/O power supply
Allowable I/O power
supply voltage
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient operating
temperature
Ambient operating
humidity
Ambient operating
environment
Ambient storage
temperature
Terminal screws
Momentary power
interruption detection
time
External dimensions
Weight
Degree of protection
Mounting method
Model
Cam Positioner Specifications
100 to 240 V AC, 50/60 Hz
85 to 264 V AC
18 VA max.
40 A/10 ms max.
24 V DC/145 mA
20.4 to 26.4 V DC
20 MΩ min. between all AC power supply external terminals and the protective
ground terminal (500 V)
2,300 V AC, 50/60 Hz for 1 minute between all AC power supply external terminals
and the protective ground terminal (leakage current of 10 mA max.)
1,500 Vp-p, pulse width of 0.1 to 1 µs, 1-ns rising pulse (noise simulator)
10 to 57 Hz, 0.075-mm single amplitude
57 to 150 Hz with an acceleration of 9.8 m/s
directions (8 minutes x 10 times = 80 minutes)
147 m/s
0 to 55°C
10 to 90% (with no condensation)
No corrosive gases
--20 to 75°C
Power supply input section:
Control I/O section:
Power interruptions of 15 ms or less are not detected.
110 × 100 × 82.5 mm (W × H × D)
1 kg max.
Panel-mounting
M4 screws (2 points) or DIN track mounting
2
, 3 times each in X, Y, and Z directions
3F88L-160
M3.5 screws
M3 screws
2
for 80 minutes each in X, Y, and Z
3F88L-162
Chapter 6