Operation
5-10
Cam outputs are strange.
Exiting of a cam program that
shouldn’t be there (CAM17 to 32).
Origin compensation has been
performed but the origin does not
p
return to 0.
The origin position is displaced.
The present angle is displaced.
The present angle is displaced.
The operation keys do not work.
g p
Problem
g
p
A new cam program has been
input without clearing the existing
cam program.
When using the advance angle
compensation function, a cam
program containing changing cam
outputs has been input near the
advance angle compensation
position/the position where the
advance angle will be
compensated (during acceleration,
cam outputs may be missed or
output twice).
When using the copy function,
data has been mistakenly copied
from another Cam Positioner
when reading data from that Cam
Positioner.
When using the copy function,
data has been mistakenly written
to another Cam Positioner when
reading data from that Cam
Positioner.
Program memory error.
When copying a cam program
from a 3F88L-160 Cam Positioner
to a 3F88L-162 Cam Positioner, a
cam program containing CAM17
to 32 has been input to the
3F88L-160 Cam Positioner (when
a cam program has been copied
to the 3F88L-160 from a
3F88L-162 beforehand.)
An origin compensation value has
been set.
The Resolver is rotating.
Circuit error.
A TRIG signal has been input.
The coupling is displaced.
The temperature variation is great. Check the ambient temperature
The Resolver cable is corrupted
and shorted with the frame ground
(FG).
Circuit error.
The functions are limited by the
function level selection.
Circuit error.
Probable cause
Check the cam program.
Set advance angle compensation
value 3 (advance angle
compensation position) to a
section where the cam outputs do
not change.
Do not use cam outputs during
acceleration as operation signals.
Check the parameters and cam
programs of the source Cam
Positioner and then perform the
copy operation.
Set the parameters for the source
Cam Positioner, and, once all cam
programs have been re-input,
perform the copy operation.
Replace the Cam Positioner.
Check the cam program and
delete any unnecessary cam
programs.
Check the origin compensation
value.
Check the machinery operation.
Replace the Cam Positioner.
Check the connection wiring.
Check the Resolver coupling.
variation.
Check the Resolver cable.
Replace the Cam Positioner.
Check and, if necessary, adjust
the function level selection
(Function No. U) and turn OFF the
power and then turn it ON again.
Replace the Cam Positioner.
Possible solution