3F88L-CR002C Omron, 3F88L-CR002C Datasheet - Page 157

no-image

3F88L-CR002C

Manufacturer Part Number
3F88L-CR002C
Description
CABLE RESOLVER FOR RS17/T 2M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CR002C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCR002C
Communications
D SRES (Subresponse Code)
“00”
“04”
“10”
“11”
“22”
“30”
MRES
“00”
“01”
“01”
“02”
“03”
“01”
“03”
“04”
“0B”
“00”
“03”
“02”
“03”
“05”
SRES
Normal completion
Unsupported command
Too long command
Too short command
Item/data count mismatch
Area type error
Beginning address range
error
End address range error
Too long response
Other parameter errors
Operation error
Write-only
Read-only
No-object error
SRES name
The service was executed normally.
The service specified in the command is not
supported.
The command length is above the maximum
length.
The command length is below the minimum
length.
The specified number of items does not match the
number of data items to be written.
The area type (such as memory area or
parameter area) is not specified correctly.
The specified beginning address is outside the
allowable range.
The specified end address (beginning address +
the number of items) is outside the allowable
range.
The response length exceeds the maximum
packet length.
Other parameter errors
Operation cannot be performed as specified.
The service cannot be executed in the current
mode.
Read is impossible due to write-only area.
Write is impossible due to read-only area.
No objects such as memory areas or parameter
areas exist.
Meaning
Chapter 4