ATMEGA16M1-MU Atmel, ATMEGA16M1-MU Datasheet - Page 298

no-image

ATMEGA16M1-MU

Manufacturer Part Number
ATMEGA16M1-MU
Description
IC MCU AVR 16K FLASH 32VQFN
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA16M1-MU

Core Processor
AVR
Core Size
8-Bit
Speed
16MHz
Connectivity
CAN, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
512 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 11x10b; D/A 1x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of I /o
-
27.9.7
27.9.8
27.9.9
27.9.10
298
ATmega16M1/32M1/64M1
Reading the EEPROM
Programming the Fuse Low Bits
Programming the Fuse High Bits
Programming the Extended Fuse Bits
The algorithm for reading the EEPROM memory is as follows (refer to
on page 295
The algorithm for programming the Fuse Low bits is as follows (refer to
on page 295
The algorithm for programming the Fuse High bits is as follows (refer to
Flash” on page 295
The algorithm for programming the Extended Fuse bits is as follows (refer to
Flash” on page 295
1. A: Load Command “0000 0011”
2. G: Load Address High Byte (0x00 - 0xFF)
3. B: Load Address Low Byte (0x00 - 0xFF)
4. Set OE to “0”, and BS1 to “0”. The EEPROM Data byte can now be read at DATA
5. Set OE to “1”
1. A: Load Command “0100 0000”
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit
3. Give WR a negative pulse and wait for RDY/BSY to go high
1. A: Load Command “0100 0000”
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit
3. Set BS1 to “1” and BS2 to “0”. This selects high data byte
4. Give WR a negative pulse and wait for RDY/BSY to go high
5. Set BS1 to “0”. This selects low data byte
1. A: Load Command “0100 0000”
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit
3. Set BS1 to “0” and BS2 to “1”. This selects extended data byte
4. Give WR a negative pulse and wait for RDY/BSY to go high
5. Set BS2 to “0”. This selects low data byte
for details on Command and Address loading):
for details on Command and Data loading):
for details on Command and Data loading):
for details on Command and Data loading):
“Programming the Flash”
“Programming the Flash”
“Programming the
“Programming the
8209D–AVR–11/10

Related parts for ATMEGA16M1-MU