M306N4FGGP#U3 Renesas Electronics America, M306N4FGGP#U3 Datasheet - Page 251

IC M16C/6N4 MCU FLASH 100-LQFP

M306N4FGGP#U3

Manufacturer Part Number
M306N4FGGP#U3
Description
IC M16C/6N4 MCU FLASH 100-LQFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/6Nr
Datasheets

Specifications of M306N4FGGP#U3

Core Processor
M16C/60
Core Size
16-Bit
Speed
24MHz
Connectivity
CAN, I²C, IEBus, SIO, UART/USART
Peripherals
DMA, WDT
Number Of I /o
85
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
10K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 26x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-LQFP
Package
100LQFP
Family Name
M16C
Maximum Speed
24 MHz
Operating Supply Voltage
3.3|5 V
Data Bus Width
16|32 Bit
Number Of Programmable I/os
87
Interface Type
I2C/UART
On-chip Adc
26-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
11
For Use With
R0K3306NKS001BE - KIT DEV RSK RSK-M16C/6NKR0K3306NKS000BE - KIT DEV RSK RSK-M16C/6NK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M306N4FGGP#U3M306N4FGGP
Manufacturer:
Evox Rifa / KEMET
Quantity:
40
Company:
Part Number:
M306N4FGGP#U3
Manufacturer:
RENESAS
Quantity:
200
Company:
Part Number:
M306N4FGGP#U3
Manufacturer:
Renesas Electronics America
Quantity:
135
Company:
Part Number:
M306N4FGGP#U3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
M16C/6N Group (M16C/6N4)
Rev.2.40
REJ09B0009-0240
19.5.5 Bus Off State
The bus off state is entered according to the fault confinement rules of the CAN specification. When
returning to CAN operation mode from the bus off state, the module has the following two cases.
In this time, the value of any CAN registers, except registers CiSTR, CiRECR, and CiTECR, does not
change.
(1) When 11 consecutive recessive bits are detected 128 times
(2) When the RetBusOff bit in the CiCTLR register = 1 (Force return from buss off)
Apr 14, 2006
The module enters instantly into error active state and the CAN communication becomes possible
immediately.
The module enters instantly into error active state, and the CAN communication becomes possible
again after 11 consecutive recessive bits are detected.
page 227 of 376
19. CAN Module

Related parts for M306N4FGGP#U3