HD6412320 RENESAS [Renesas Technology Corp], HD6412320 Datasheet - Page 848

no-image

HD6412320

Manufacturer Part Number
HD6412320
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family H8S-2300 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412320VF25
Manufacturer:
HITACHI
Quantity:
1 045
Part Number:
HD6412320VF25IV
Manufacturer:
SEIKO
Quantity:
4 100
Part Number:
HD6412320VF25IV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412320VF25V
Manufacturer:
RENESAS
Quantity:
1 592
Part Number:
HD6412320VTE25
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6412320VTE25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412320VTE25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 19 ROM
Next, the watchdog timer is set to prevent overprogramming in the event of program runaway, etc.
Set a value greater than (y + z2 + α + β) µs as the WDT overflow period. After this, preparation
for program mode (program setup) is carried out by setting the PSU bit in FLMCR1, and after the
elapse of (y) µs or more, the operating mode is switched to program mode by setting the P bit in
FLMCR1. The time during which the P bit is set is the flash memory programming time. Set the
programming time according to the table in the programming flowchart.
19.16.2 Program-Verify Mode
In program-verify mode, the data written in program mode is read to check whether it has been
correctly written in the flash memory.
After the elapse of a given programming time, the programming mode is exited (the P bit in
FLMCR1 is cleared to 0, then the PSU bit is cleared to 0 at least (α) µs later). Next, the watchdog
timer is cleared after the elapse of (β) µs or more, and the operating mode is switched to program-
verify mode by setting the PV bit in FLMCR1. Before reading in program-verify mode, a dummy
write of H'FF data should be made to the addresses to be read. The dummy write should be
executed after the elapse of (γ) µs or more. When the flash memory is read in this state (verify data
is read in 16-bit units), the data at the latched address is read. Wait at least (ε) µs after the dummy
write before performing this read operation. Next, the originally written data is compared with the
verify data, and reprogram data is computed (see figure 19.41) and transferred to the reprogram
data area. After 128 bytes of data have been verified, exit program-verify mode, wait for at least
(η) µs, then clear the SWE bit in FLMCR1 to 0, and wait again for at least (θ) μs. If
reprogramming is necessary, set program mode again, and repeat the program/program-verify
sequence as before. However, ensure that the program/program-verify sequence is not repeated
more than (N) times on the same bits.
Rev.6.00 Sep. 27, 2007 Page 818 of 1268
REJ09B0220-0600