HD6412320 RENESAS [Renesas Technology Corp], HD6412320 Datasheet - Page 639

no-image

HD6412320

Manufacturer Part Number
HD6412320
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family H8S-2300 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412320VF25
Manufacturer:
HITACHI
Quantity:
1 045
Part Number:
HD6412320VF25IV
Manufacturer:
SEIKO
Quantity:
4 100
Part Number:
HD6412320VF25IV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412320VF25V
Manufacturer:
RENESAS
Quantity:
1 592
Part Number:
HD6412320VTE25
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6412320VTE25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412320VTE25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Bit 3—Multiprocessor Interrupt Enable (MPIE): Enables or disables multiprocessor interrupts.
The MPIE bit setting is only valid in asynchronous mode when the MP bit in SMR is set to 1.
The MPIE bit setting is invalid in synchronous mode or when the MP bit is cleared to 0.
Bit 3
MPIE
0
1
Note: * When receive data including MPB = 0 is received, receive data transfer from RSR to RDR,
Bit 2—Transmit End Interrupt Enable (TEIE): Enables or disables transmit-end interrupt
(TEI) request generation when there is no valid transmit data in TDR in MSB data transmission.
Bit 2
TEIE
0
1
Note: * TEI cancellation can be performed by reading 1 from the TDRE flag in SSR, then clearing it
Bits 1 and 0—Clock Enable 1 and 0 (CKE1, CKE0): These bits are used to select the SCI clock
source and enable or disable clock output from the SCK pin. The combination of the CKE1 and
CKE0 bits determines whether the SCK pin functions as an I/O port, the serial clock output pin, or
the serial clock input pin.
The setting of the CKE0 bit, however, is only valid for internal clock operation (CKE1 = 0) in
asynchronous mode. The CKE0 bit setting is invalid in synchronous mode, and in the case of
external clock operation (CKE1 = 1). Set CKE1 and CKE0 before determining the SCI operating
mode with SMR.
receive error detection, and setting of the RDRF, FER, and ORER flags in SSR, is not
performed. When receive data including MPB = 1 is received, the MPB bit in SSR is set to
1, the MPIE bit is cleared to 0 automatically, and generation of RXI and ERI interrupts
(when the TIE and RIE bits in SCR are set to 1) and FER and ORER flag setting is enabled.
to 0 and clearing the TEND flag to 0, or by clearing the TEIE bit to 0.
Description
Multiprocessor interrupts disabled (normal reception performed)
[Clearing conditions]
Multiprocessor interrupts enabled *
Receive-data-full interrupt (RXI) requests, receive-error interrupt (ERI) requests, and
setting of the RDRF, FER, and ORER flags in SSR are disabled until data with the
multiprocessor bit set to 1 is received.
Description
Transmit end interrupt (TEI) request disabled *
Transmit end interrupt (TEI) request enabled *
When the MPIE bit is cleared to 0
When data with MPB = 1 is received
Section 14 Serial Communication Interface (SCI)
Rev.6.00 Sep. 27, 2007 Page 609 of 1268
REJ09B0220-0600
(Initial value)
(Initial value)