CN8237
ATM OC-12 ServiceSAR Plus with xBR Traffic Management
0x150
28237-DSH-001-C
15–14
31-16
13–0
Bit
Bit
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Schedule Size Register (SCH_SIZE)
Field
Field
Size
Size
16
14
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
GFC15
Reserved
TUN_ENA_14
GFC14
Reserved
TUN_ENA_13
GFC13
Reserved
TUN_ENA_12
GFC12
Reserved
TUN_ENA_11
GFC11
Reserved
TUN_ENA_10
GFC10
Reserved
TUN_ENA_9
GFC9
Reserved
TUN_ENA_8
GFC8
TBL_SIZE[15:0]
Reserved
SLOT_PER[13:0]
The SCH_SIZE register sets the size of the schedule table in schedule slots and
the period of a schedule slot in system clocks.
Name
Name
Mindspeed Technologies
Enable GFC on global priority pointer 15.
Program and read as 0.
Enable tunnel on global priority pointer 14.
Enable GFC on global priority pointer 14.
Program and read as 0.
Enable tunnel on global priority pointer 13.
Enable GFC on global priority pointer 13.
Program and read as 0.
Enable tunnel on global priority pointer 12.
Enable GFC on global priority pointer 12.
Program and read as 0.
Enable tunnel on global priority pointer 11.
Enable GFC on global priority pointer 11.
Program and read as 0.
Enable tunnel on global priority pointer 10.
Enable GFC on global priority pointer 10.
Program and read as 0.
Enable tunnel on global priority pointer 9.
Enable GFC on global priority pointer 9.
Program and read as 0.
Enable tunnel on global priority pointer 8.
Enable GFC on global priority pointer 8.
Size of schedule table in schedule slots.
Program and read as 0.
Number of system clocks per schedule slot. The value written to the
register should be (SLOT_PER – 1). Minimum bound for SLOT_PER
value = 40.
Description
Description
14.0 CN8237 Registers
14.4 Scheduler Registers
14-15