AT90PWM81 Atmel Corporation, AT90PWM81 Datasheet - Page 52

no-image

AT90PWM81

Manufacturer Part Number
AT90PWM81
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT90PWM81

Flash (kbytes)
8 Kbytes
Pin Count
20
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
20
Ext Interrupts
3
Usb Speed
No
Usb Interface
No
Spi
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
10
Adc Speed (ksps)
125
Analog Comparators
3
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.25
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 125
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
1
Output Compare Channels
8
Input Capture Channels
1
Pwm Channels
6
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90PWM81-16MF
Manufacturer:
Atmel
Quantity:
3 118
Part Number:
AT90PWM81-16MN
Manufacturer:
Atmel
Quantity:
2 446
Part Number:
AT90PWM81-16SF
Manufacturer:
Atmel
Quantity:
2 428
Part Number:
AT90PWM81-16SN
Manufacturer:
Atmel
Quantity:
1 500
7.1.5
52
AT90PWM81
Brown-out Detection
AT90PWM81 has an On-chip Brown-out Detection (BOD) circuit for monitoring the V
operation by comparing it to a fixed trigger level. The trigger level for the BOD can be selected by the
BODLEVEL Fuses. The trigger level has a hysteresis to ensure spike free Brown-out Detection. The hys-
teresis on the detection level should be interpreted as V
V
Table 7-2.
Notes:
Table 7-3.
Notes:
When V
immediately activated. When V
ter starts the MCU after the Time-out period t
The BOD circuit will only detect a drop in V
t
BOD
Symbol
V
t
HYST
BOD
HYST
given in
/2.
BODLEVEL 2..0 Fuses
CC
1. V
2. Values are guidelines only.
1. Values are guidelines only.
( default configuration)
decreases to a value below the trigger level (V
case, the device is tested down to V
Out Reset will occur before V
longer guaranteed. The test is performed using BODLEVEL = 010 for Low Operating Voltageand
BODLEVEL = 101for High Operating Voltage.
Table
BOT
BODLEVEL Fuse Coding
Brown-out Characteristics
Parameter
Brown-out Detector Hysteresis
Min Pulse Width on Brown-out Reset
may be below nominal minimum operating voltage for some devices. For devices where this is the
110
101
100
011
010
001
000
111
7-3.
CC
increases above the trigger level (V
CC
drops to a voltage where correct operation of the microcontroller is no
(1)
(1)(2)
Min V
CC
CC
TOUT
3.9
2.5
= V
if the voltage stays below the trigger level for longer than
BOT
BOT
has expired.
during the production test. This guarantees that a Brown-
Forbidden, BOD must be enabled
BOT+
BOT-
Typ V
Min.
= V
4.5
2.7
4.3
4.4
4.2
2.8
2.7
in
BOT
Figure
BOT
BOT+
+ V
Typ.
in
70
7-5), the Brown-out Reset is
2
HYST
Figure
Max V
/2 and V
4.6
2.9
7-5), the delay coun-
Max.
BOT
CC
7734P–AVR–08/10
BOT-
level during
= V
Units
Units
mV
V
V
V
V
V
V
V
µs
BOT
-

Related parts for AT90PWM81