AT90PWM81 Atmel Corporation, AT90PWM81 Datasheet - Page 169

no-image

AT90PWM81

Manufacturer Part Number
AT90PWM81
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT90PWM81

Flash (kbytes)
8 Kbytes
Pin Count
20
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
20
Ext Interrupts
3
Usb Speed
No
Usb Interface
No
Spi
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
10
Adc Speed (ksps)
125
Analog Comparators
3
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.25
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 125
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
1
Output Compare Channels
8
Input Capture Channels
1
Pwm Channels
6
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90PWM81-16MF
Manufacturer:
Atmel
Quantity:
3 118
Part Number:
AT90PWM81-16MN
Manufacturer:
Atmel
Quantity:
2 446
Part Number:
AT90PWM81-16SF
Manufacturer:
Atmel
Quantity:
2 428
Part Number:
AT90PWM81-16SN
Manufacturer:
Atmel
Quantity:
1 500
13.18.1
13.18.2
13.18.3
13.19 Analog Synchronization
7734P–AVR–08/10
Available Input Mode according to Running Mode
Event Capture
Using the Input Capture Unit
Some Input Modes are not consistent with some Running Modes. So the table below gives the input
modes which are valid according to running modes.
Table 13-6.
The PSCR can capture the value of time (PSCR counter) when a retrigger event or fault event occurs on
PSCR inputs. This value can be read by software in PICRrH/L register.
The main challenge when using the Input Capture unit is to assign enough processor capacity for handling
the incoming events. The time between two events is critical. If the processor has not read the captured
value in the PICR1 Register before the next event occurs, the PICR1 will be overwritten with a new value.
In this case the result of the capture will be incorrect.
When using the Input Capture interrupt, the PICR1 Register should be read as early in the interrupt han-
dler routine as possible. Even though the Input Capture interrupt has relatively high priority, the maximum
interrupt response time is dependent on the maximum number of clock cycles it takes to handle any of the
other interrupt requests.
PSCR generates a signal to synchronize the sample and hold; synchronization is mandatory for
measurements.
Input Mode Number :
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Available Input Modes according to Running Modes
1 Ramp Mode
Valid
Do not use
Do not use
Valid
Do not use
Do not use
Valid
Valid
Valid
Do not use
Valid
Do not use
2 Ramp Mode
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
AT90PWM81
4 Ramp Mode
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
169