EP4CE40F29C8N Altera, EP4CE40F29C8N Datasheet - Page 406

no-image

EP4CE40F29C8N

Manufacturer Part Number
EP4CE40F29C8N
Description
IC CYCLONE IV FPGA 40K 780FBGA
Manufacturer
Altera
Series
CYCLONE® IV Er

Specifications of EP4CE40F29C8N

Number Of Logic Elements/cells
39600
Number Of Labs/clbs
2475
Total Ram Bits
1134000
Number Of I /o
532
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA43
Quantity:
1 602
Part Number:
EP4CE40F29C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CE40F29C8N
0
Company:
Part Number:
EP4CE40F29C8N
Quantity:
2 800
Part Number:
EP4CE40F29C8N ALTERA
Manufacturer:
ALTERA
0
3–16
Figure 3–7. Read Transaction Waveform—Use the same control signal for all the channels Option Enabled
Note to
(1) In this waveform example, you want to read from only the transmitter portion of all the channels.
Cyclone IV Device Handbook, Volume 2
Figure
rx_tx_duplex_sel [1:0]
tx_vodctrl_out [2:0]
3–7:
1
reconfig_clk
data_valid
To complete a read transaction to the V
following steps:
1. Before you initiate a read transaction, set the rx_tx_duplex_sel port to 2'b10 so
2. Ensure that the busy signal is low before you start a read transaction.
3. Assert the read signal for one reconfig_clk clock cycle. This initiates the read
4. The busy output status signal is asserted high to indicate that the dynamic
5. When the read transaction has completed, the busy signal goes low. The
6. To read the current V
In the waveform example shown in
channels 1 and 2 prior to the read transaction are 3'b001 and 3'b010, respectively.
Simultaneous write and read transactions are not allowed.
busy
read
that only the transmit PMA controls are read from the transceiver channel.
transaction.
reconfiguration controller is busy reading the PMA control settings.
data_valid signal is asserted, indicating that the data available at the read control
signal is valid.
tx_vodctrl_out[5:3].
(1)
2'b00
OD
values in channel 2, observe the values in
6'b111111
Figure
OD
values of the second channel, perform the
3–7, the transmit V
2'b10
Chapter 3: Cyclone IV Dynamic Reconfiguration
6'bXXXXXX
© December 2010 Altera Corporation
OD
Dynamic Reconfiguration Modes
settings written in
6'b010001

Related parts for EP4CE40F29C8N